Swedish Medical Center / Craig Hospital campus
Major healthcare cluster at Girard and Hampden; full life-safety stacks, medical-gas rooms, generator and fire-pump testing, and smoke-control systems on the acute-care towers.
Colorado Front Range • Arapahoe County
Englewood packs a lot of high-consequence property into a small footprint: the Swedish Medical Center and Craig Hospital campus at Girard and Hampden, the CityCenter Englewood redevelopment on the old Cinderella City site next to the light-rail station, and decades of industrial buildings along the Santa Fe corridor. Fire service here is delivered by South Metro Fire Rescue, which took over Englewood fire services in 2015, and every inspection report we write is built to pass their review on the first submittal. Our office at 7076 S. Alton Way in Centennial is about fifteen minutes down Broadway, so a technician who knows your building is close.

South Metro Fire Rescue is the Authority Having Jurisdiction for Englewood and conducts the fire inspections for commercial, multi-family, and institutional properties in the city. Its non-emergency line is (720) 989-2000, and permitting and code information is at https://www.southmetro.org/. We schedule inspection and testing work with your on-site team and format every deficiency list to match what South Metro Fire Rescue’s prevention staff expect, so corrections get signed off without rework.
Englewood runs from the Swedish/Craig hospital district on Hampden down through the South Broadway retail spine to the industrial blocks along Santa Fe Drive. That range — acute-care towers, transit-oriented redevelopment, and pre-war warehouses — is why our technicians carry parts for both a modern smoke-control system and a 1950s dry-pipe valve. Below are the areas we cover most.
Major healthcare cluster at Girard and Hampden; full life-safety stacks, medical-gas rooms, generator and fire-pump testing, and smoke-control systems on the acute-care towers.
The redeveloped Cinderella City site at the light-rail station — civic buildings, retail, and residential above ground-floor commercial with kitchen-hood suppression and radio-coverage scopes.
The city’s retail and small-business spine; storefront occupancies, restaurants, and older mixed-use buildings with legacy sprinkler and alarm layouts.
Older warehouse and manufacturing along the rail and river; dry-pipe systems, fire pumps, and rack-storage commodity classification are recurring scopes.
Original commercial core near Hampden and Broadway; small retail, offices, and upper-floor residential in buildings that predate current code.
Transit-oriented development on the South Platte side of the light rail; mid-rise residential and flex space with monitored alarm and standpipe systems.
Compact pre-1960 single-family bungalows and small apartment courts; monitored smoke detection and extinguisher service dominate.
Established residential neighborhood west of Broadway; older homes, small multi-family, and church occupancies.
Grocery-anchored strips and auto-service along Belleview; Ansul kitchen-hood systems and sprinkler-obstruction clearances are common findings.
Interior single-family grid east of Broadway; residential monitoring and extinguisher work.
Auto dealers, quick-service restaurants, and light commercial on the western boundary; hood suppression and paint-booth hazard scopes.
High-traffic east-west spine feeding the hospital district; medical office buildings, hotels, and multi-story commercial with full alarm systems.
Every service below is run by NICET- or CSA-certified technicians, with reports formatted to South Metro Fire Rescue’s preferred layout — so corrections clear on the first review instead of a second visit.
Sprinklers, alarms, extinguishers, backflow, and suppression — each system tested on its own code cadence and documented in one report formatted for South Metro Fire Rescue review.
Wet, dry, preaction, deluge, and standpipe systems exercised per NFPA 25 — critical for the dry-pipe systems in Santa Fe corridor warehouses and the standpipes serving the hospital towers on Hampden.
Initiating devices, notification appliances, control panels, and secondary power tested to NFPA 72 by NICET-certified technicians, including the addressable systems common in CityCenter and Hampden medical offices.
UL-listed central station monitoring with signal verification and fire-watch protocols, with direct dispatch to South Metro Fire Rescue when an alarm confirms.
Annual cross-connection control testing for irrigation, fire-line, and domestic backflow preventers; certification filed with the Englewood Utilities Department.
Annual inspections, six-year maintenance, twelve-year hydrostatic testing, and on-site recharging for Class A through Class K hazards, including Class D units in Santa Fe metal shops.
UL-300 wet-chemical and Ansul R-102 systems inspected, tested, and tagged per NFPA 96 and 17A — a recurring scope for the restaurants along South Broadway and the Belleview retail strips.
FM-200, Novec 1230, and CO₂ systems for hospital IT rooms, imaging suites, and server closets in the Swedish/Craig campus and Hampden medical office buildings.
Plan-review coordination with South Metro Fire Rescue, phasing plans for occupied healthcare renovations, and deficiency-correction project management for property-management and hospital-facilities teams.
These are the recurring deficiency categories we see across Englewood properties, from the hospital district to the Santa Fe warehouses. None of this is a citation from a specific building — it’s the pattern of findings our technicians document and correct most often in this jurisdiction.
Santa Fe Drive warehouses accumulate racking, mezzanines, and tenant build-outs that crowd sprinkler deflectors over the years. We measure clearance to the inch and document the correction scope so South Metro Fire Rescue signs off fast.
The unheated warehouses and loading docks along the rail corridor run dry-pipe systems that miss their quarterly trip checks and 3-year full-flow trip tests. We track every dry system’s trip cadence and exercise the valve before it fails an inspection.
Sealed lead-acid backup batteries have a 4–5 year service life, and failed load tests are a top finding across Broadway and Hampden commercial buildings. We log each panel’s battery age and replace proactively.
Fire-line and irrigation backflow preventers require annual testing by a certified cross-connection tester. We file the certification directly with the Englewood Utilities Department and note it on the AHJ report.
Pre-UL-300 wet-chemical systems still turn up in older South Broadway kitchens. We inventory hood systems by hazard class and flag UL-300 conversions ahead of lease renewal or a health-and-fire re-inspection.
Occupied renovations on the Swedish/Craig campus can leave smoke-control tests, fire-pump churn records, or generator load logs incomplete. We rebuild the ITM documentation trail so it withstands both AHJ and accreditation review.
Missing or broken FDC caps let debris into the check valve and can fail an inspection outright — a common finding on the older standpipe systems downtown. We carry replacements and install them on the spot.
Englewood’s building stock is older and denser than its south-metro neighbors, with a large share of the single-family and small multi-family housing built before 1960 in the neighborhoods flanking Broadway. The dominant commercial anchor is the Swedish Medical Center and Craig Hospital campus, a high-rise acute-care and rehabilitation complex that carries some of the most demanding life-safety requirements in the county — smoke-control, medical-gas shutoffs, emergency power, and fire-pump reliability all under continuous occupancy. The CityCenter Englewood redevelopment brought mixed-use retail and residential to the former Cinderella City mall site beside the light-rail station, while the Santa Fe Drive corridor still holds decades-old warehouse and manufacturing space along the rail line and the South Platte. South Broadway carries the city’s storefront retail and restaurants, many in buildings that predate current sprinkler and alarm requirements and rely on retrofit scopes at tenant turnover.
Englewood transitioned fire services to South Metro Fire Rescue in 2015, so South Metro Fire Rescue is the authority that conducts on-site fire inspections and enforces the fire code for properties in the city. Permitting and plan-review contacts should be confirmed directly with South Metro Fire Rescue; call Red Rocks Fire Protection to schedule the inspection and testing work itself.
Our office is at 7076 S. Alton Way, Suite G2, Centennial, CO 80112 — roughly fifteen minutes from downtown Englewood down South Broadway or across on Hampden. Because Englewood is well inside the Denver metro, we hold a 90-minute emergency response window for fire-protection emergencies in the city, and we send technicians who already know your building rather than a rotating crew.
Yes. Healthcare facilities carry the most demanding life-safety scopes in Englewood — smoke-control testing, fire-pump reliability, medical-gas shutoffs, emergency-power coordination, and clean-agent suppression for imaging and IT rooms — all under continuous occupancy. We phase this work around patient care and keep the ITM records complete for both South Metro Fire Rescue and accreditation review.
Per NFPA 25 and the IFC as adopted, wet-pipe sprinkler systems require quarterly and annual inspections with an internal inspection every 5 years. Dry-pipe systems — common in the Santa Fe corridor warehouses — add quarterly trip tests and a 3-year full-flow trip test. We track every cadence and email you 30 days before a test is due.
Much of the housing and storefront commercial flanking South Broadway and downtown Hampden predates current sprinkler and alarm requirements. When those buildings change use or a tenant renovates, the fire code triggers upgrades — added coverage, addressable alarm devices, or a monitored connection. We scope the retrofit against the current adopted code so the project clears South Metro Fire Rescue review the first time.
Yes. NFPA 96 and the IFC require an automatic fire-extinguishing system for commercial cooking operations, covering the hood, duct, and plenum. UL-300 wet-chemical systems are the current standard. Older systems in South Broadway and Belleview kitchens are grandfathered but usually need replacement at tenant turnover or a major renovation.
Yes. Unheated warehouse and loading-dock space along Santa Fe Drive runs on dry-pipe sprinkler systems that need quarterly trip checks and a 3-year full-flow trip test per NFPA 25. We exercise the dry valve, verify the air-pressure and quick-opening devices, and correct the low-point drains that cause most trip-test failures.
Englewood is inside the Denver metro and a short drive from our Centennial office, so our emergency response window for fire-protection emergencies in the city is typically under 90 minutes and usually faster. We staff a 24/7 line and dispatch the same technicians who know your property, not a call center.
Choosing the right life safety partner for your properties is about more than maintaining systems and meeting requirements. It's about having a local team you can trust to communicate clearly, advocate for you, stay ahead of compliance, and take responsibility for protecting your people and property across the Front Range.
At Red Rocks Fire Protection Services, we want to be more than another vendor. We want to be your trusted life safety partner for years to come.
Ready to start the conversation? Call us at (720) 733-8050 or Contact Us to connect with our team.
Want to learn more about what makes Red Rocks Fire Protection Services different?
Explore the pages below to discover our commitment to safety, our purpose, and the promises that guide every relationship we build.